DR9000S Coating Thickness Gauge it’s a Large Range Coating Thickness Gauge,test Magnetic thickness method, can be nondestructively measuring magnetic metal matrix ( such as: steel, iron, nickel ) on non magnetic coatings thickness ( such as: galvanized, chrome, paint, electrophoresis, enamel, rubber, powder coating, Anticorrosive coatings, bitumen and fire retardant coatings, etc.)
Coating thickness characteristics
A、Fine small integrated, convenient to carry
B、Metal probe,Simple operation, quick test speed
C、Two test methods: a continuous test and a single measuring method
D、Four statistical functions: maximum value, minimum value, average value, the number of measurements
E、Two calibration methods: zero calibration and two point calibration
F、Operation process has the buzz sound prompt ( single measurement )
G、Automatic recognition of Fe and NFe substrates
H、Low voltage indication
I、Metallic test head, wear resistance, not easy to damage
J、Manual / automatic shutdown function
technical parameters
A、Measuring range:0-9500μm(0-9.5mm)
B、Using environment: 0℃-50℃and 20%RH—90%RH,not strong magnetic place.