自動在線SDI儀(以色列)
參考價 | 面議 |
具體成交價以合同協議為準
- 型號 型號:MSDI-2201
- 品牌
- 廠商性質 生產商
- 所在地 北京市
更新時間:2023-03-24 16:18:56瀏覽次數:1031
聯系我們時請說明是環保在線上看到的信息,謝謝!
產品簡介
自動在線SDI儀(以色列) 型號:MSDI-2201 |
|
1個采樣點 1通道模擬輸出 ● 在測量之前沖洗管路 ● 控制水壓范圍 ● 測量流量 ● 切換濾膜 ● 每個測試過程完成后排水并清洗系統 ● 測量方式可編程 ● 監控已執行程序 ● 大容量數據存儲 ● 實時SDI值和狀態顯示 ● 可編程的限報警 ● 自檢和錯誤狀態報警 ● 可選的遠程監控 220/110VAC到24VDC電源轉換 彩色觸摸屏顯示器 10個6米長濾膜卷 1. Introduction 1.1. General Description Multi Channel On-Line Quality Water Analyzer, SDI-2200 he SDI 2200 Automatic, On Line, Silt Density Index Monitoring System is a unique on-line control system, designed for continuous, unattended operation in desalination and other water treatment plants. T The SDI 2200 is used in critical water quality applications, where precise control is essential for safe and economic operation. It replaces the manual, error prone, conventional procedure with an automatic, precise and infallible routine. The SDI 2200 is a complete self-contained system meant for unattended operation with extensive reliability and with advanced fault analysis and warning. The rugged, spray proof (IP 53) wall mountable system performs all the below steps that are required for quality water testing results: ƒ Flushes pipes prior to measurement. ƒ Controls water pressure. ƒ Measures flow rate. ƒ Replaces filter. ƒ Drains the water and cleans the system at th ƒ Programmability of the measurement protoc ƒ Monitors executed program. ƒ Data logging in digital memory. ƒ Real time SDI and status display. SDI-2200 ƒ Programmable alarm on over-limit levels. ƒ Self-test and fault conditions alarm. ƒ Optional dry contact and analog signals for remote control and monitoring. The Display panel provides the operator with interface and on-line control to the Analyzer control functions. There are four possible input channels for the SDI-2200 driven analyzers categorized as follows: ƒ 1 Channel Analyzer: SDI-2201 ƒ 2 Channel Analyzer: SDI-2202 ƒ 3 Channel Analyzer: SDI-2203 ƒ 4 Channel Analyzer: SDI-2204 1.2. Principals of Operation Standard Test Mode Silt Density Index (SDI) is measured by comparing the flow rate of a known quantity of water, where the water quantity is kept under constant pressure. The flow rate is measured twice, once where the water flows through a standard filter, as a reference, when the filter is unused, and the second time after the filter is exposed for 1-15 minutes, and the water sample flow is kept always under constant pressure. The drop in flow rate is a direct measure of the silt build-up on the filter. The flow rate is derived from quantities and timing information: 1 ? ? ? ? − i tSDI = 100 1 × ? ? ? ? ? ? ? ? − τ f i t t Where: initial time required to collect 500 [mL] of sample, time required to collect 500 [mL] of sample after test time t t: total elapsed flow time, min. (usually Standard Measured Time1 ) The SDI 2200 provides the same type of measurement both in automatic nd in on-line mode for up to four independent sampling points. The pressure is kept constant by precisely regulated air pressure applied on he water surface without the need of any mechanical device. Auto Time Test Mode n cases where the silt density index (SDI) reading is unstable and eadings are higher then 5 (i.e. Plugging Factor is higher then 75%), during the 15 minutes check time, the Analyzer can be programmed to work in AUTO TIME TEST MODE based on the following test method automatically: ƒ The %P30 (Plugging Factor) calculations will proceed and recorded in intervals of one-minute elapsed. ƒ Calculations will stop once %P30 (Plugging Factor) 75% has been reached. ƒ New SDI2 readings will be displayed based on the last calculated plugging factor at the last measured time also check time will be displayed. All SDI test readings are on 0-100 scale where the exact check time figure has no valuable meaning as in the Standard Test Mode. In general, the higher the SDI reading the more silt is in the water. When the plugging factor after 15 minutes is calculated to be lower then 75%, the Analyzer will switch and calculate the test results based on the Standard Method. %P30 = 100 1 × ? ? ? ? ? ? ? ? − f i t t Where: %P30: plugging factor at 30 [psi] feed pressure, ti : initial time required to collect 100 [mL] of sample, 1 Standard Measuring Time (SMT) is 15 minutes. The higher the expected SDI value, the lower the SMT value. The SMT scale value ranges from 1–15. 2 - if after 15 minutes the readings are lower then 75% results are being calculated as per the Standard method. The higher the SDI readings the more silt are in the water. Page 9 of 69 Rev. 1.0 SDI-2200 OPERATING MANUAL (COLOR) 1 0.DOC 1.3. System and Product Specifications TECHNICAL INFORMATION: Dimensions (in mm) W= 760 D= 500 H=260 Dimensions (in In) W= 30 D= 20 H=10.25 Weight 40[Kg], or 85[Lb] CONSTRUCTION MATERIAL: Wet Parts PVC Construction Container Polyester UTILITY SPECIFICATIONS: Supply In: Water Pressure 2.4 to 6.0 [Bar] or 35 to 90 [Psig] Water Flow Rate 1.5 [L/min.] or 0.5 [Gal/min.] Air Pressure 5.2 to 8.0 [Bar] or 80-120 [Psig] Electrical 24 [VDC], 2 [Amp] Slit Density Index (SDI) ranges 0.00-99.99 SDI Check time 1-15[Minutes] Output Signal: Option 1: Dry contact for common alarm indication and fault indication Option 2: Two dry contact for common alarm indication and fault indication Option 3: Dry contact for Ready indication Option 4: Dry contact for each channel alarm indication Option 5: Analog isolated output per channel 0-5 [Volt], 1-5[Volts], 0- 20[mA] and 4-20[mA]. Input Signal: Option 1: Remote Start/Stop input Dry Contact Option 2: Remote Start for each input Dry Contact Filter Paper Type Rolls, length 6 [Meter] or 20 [Ft], 90 measurements per roll. Drain PVC Environment protection: IP53 1.4. SDI Analyzer Type and description: Analyzer format definition - SDI 220n-a-b-c Where: n: Number of Channels (1 - 4). a: Number of Analog Outputs (1 - 4). Specified ranges: ƒ 0-5 [Volts] ƒ 1-5 [Volts] ƒ 0-20 [mA] ƒ 4-20 [mA] Note: The Analog Output is directly related to the SDI reading (see- setting the analog range 3.2.7). b: Where: 0 - No Relay Alarm Output. 1-5 - One to five Alarm Outputs. c: Where: 0 - No Remote Start/Stop Input. 1 - With Remote Start/Stop Input. Examples: SDI 2202-2-0-0 range 0-5 [Volt] for Analyzer with two inputs and two analog (0-5[Volt]) outputs and no alarm relay outputs nor remote start input, with local panel. SDI 2204-3-1-1-range 1-5 [Volt] for Analyzer with four inputs and three analog (1-5 [Volt]) outputs, alarm relay outputs and remote start input. SDI 2202-2-0 range 0-20 [mA] for Analyzer with two inputs and two analog (0-20 [mA]) outputs and no alarm relay outputs, with local display panel. 1.4.1. Analyzer Configuration The SDI-2200 consists of sing le non-portable unit. Overall system representation and detailed views are shown below: In the Table 1 below, the Analyzer is presented in the center column with a view of the front door open. Picture of the side view in the right column: Analyzer | 自動在線SDI儀(以色列)MSDI-2201![]() |
該公司其他分類產品信息查看所有產品
- 筆型葉片頻率測量分析儀 型號:BT17-FM1300A庫號:M240779面議
- 生化分析儀(封閉式) 型號:BK25-BK-400庫號:M404631面議
- 噪聲類/聲級計類/噪聲頻譜分析儀(含打印機) 型號:JH8HS6298B庫號:M351514面議
- 供應多參數水質分析儀庫號:M296169面議
- 傳感分析儀 (雙膜雙電極)乙醇-葡萄糖分析儀 型號:XLFX-SBA-40C庫號:M171691面議
- 微量氧分析儀庫號:M404664面議
- 供應振動分析儀庫號:M317920面議
- (LQS)總有機碳分析儀型號:YX09-TOC-2000庫號:M104727面議
- (LQS)便攜式果品近紅外分析儀(光纖) 型號:FE01-FN502C庫號:M404671面議
- (LQS)臺式果品近紅外分析儀 型號:FE01-FN501C庫號:M404670面議
北京海富達科技有限公司
環保在線 設計制作,未經允許翻錄必究.Copyright(C) http://www.598km.com, All rights reserved.
以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,環保在線對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。